Pairs/triples twisted cables for telecommunication and instrumentation, overall screened, armoured and fire resistant

Construction

CONDUCTOR

PLAIN ANNEALED COPPER OR TINNED ANNEALED COPPER CONDUCTOR CL. 2, ACC. TO IEC 60228, DIN VDE 0295

INSULATION

MICA GLASS TAPE + GAALTHERM® 595

CORES COLOR

PAIR: BLACK- LIGHT BLUE TRIPLE: BLACK- LIGHT BLUE - BROWN

STRANDING

CORE LAID-UP TOGETHER IN PAIRS/TRIPLES

OVERALL SCREEN

ALUMINIUM/POLYESTER TAPE WITH TINNED ANNEALED COPPER STRANDED DRAIN WIRE

ARMOUR

PLAIN OR TINNED ANNEALED COPPER WIRES BRAID ACC. TO IEC 60092-350

OUTER SHEATH

HALOGEN FREE THERMOPLASTIC COMPOUND SHF1 ACC. TO IEC 60092-360, THICKNESS ACC. TO IEC 60092-376

MARKING

ELETTROTEK KABEL® GAALSHIP® HF 250 OSA FR, CROSS NOMINAL SECTION SQMM, 150/250 V, PART N°, IEC 60092-376, IEC 60332-3-22, IEC 60331, PRODUCTION PLANT, BATCH N°, PRODUCTION DATE, CE ROHS, PROGRESSIVE METER MARKING

Features

  • SHEATHING AND INSULATING MATERIALS ACC. TO IEC 60092-360
  • DESIGN GUIDELINES ACC. TO IEC 60092-350/376
  • CHOICE AND INSTALLATION OF ELECTRIC CABLES ACC. TO IEC 60092-352
  • COLD BEND TEST AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-40°C)
  • COLD BEND IMPACT AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-35°C)
  • ON REQUEST CLASS 5 CONDUCTOR ACC. TO IEC 60228

Resistance

FIRE RESISTANT ACC. TO

IEC 60331-21
IEC 60331-2 (UNDER 20 MM Ø) IEC 60331-1 (OVER 20 MM Ø

FLAME AND FIRE RETARDANT ACC. TO

EN IEC 60332-1-2,
EN IEC 60332-3-22

HALOGEN FREE ACC. TO

EN IEC 60754-1/2

SMOKE EMISSION PROPERTIES ACC. TO

EN IEC 61034-1/2

Application

Fire resistant instrumentation cables for fi xed electrical
installations aboard ships, screened against electromagnetic
interferences, complying with IEC 60092-352

Technical data

NOMINAL VOLTAGE :

150/250 V

TEMPERATURE RANGE :

INSTALLATION TEMP.

 

-5°C

-40°C UP TO +90° C

SHORT CIRCUIT TEMPERATURE :

+250°C

MIN. BENDING RADIUS :

4 x OUTER DIAMETER