Gaalship®
HF 250 OSA FR
Pairs/triples twisted cables for telecommunication and instrumentation, overall screened, armoured and fire resistant
Features
- SHEATHING AND INSULATING MATERIALS ACC. TO IEC 60092-360
- DESIGN GUIDELINES ACC. TO IEC 60092-350/376
- CHOICE AND INSTALLATION OF ELECTRIC CABLES ACC. TO IEC 60092-352
- COLD BEND TEST AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-40°C)
- COLD BEND IMPACT AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-35°C)
- ON REQUEST CLASS 5 CONDUCTOR ACC. TO IEC 60228
Resistance
FIRE RESISTANT ACC. TO
IEC 60331-21
IEC 60331-2 (UNDER 20 MM Ø) IEC 60331-1 (OVER 20 MM Ø
FLAME AND FIRE RETARDANT ACC. TO
EN IEC 60332-1-2,
EN IEC 60332-3-22
HALOGEN FREE ACC. TO
EN IEC 60754-1/2
SMOKE EMISSION PROPERTIES ACC. TO
EN IEC 61034-1/2
Application
Fire resistant instrumentation cables for fi xed electrical
installations aboard ships, screened against electromagnetic
interferences, complying with IEC 60092-352