Gaalship®

HF 250 OSA

NXT Version, North America Color Code, pairs/triads twisted cables for telecommunication and instrumentation, overall shielded, armoured

Construction

CONDUCTOR

TINNED ANNEALED COPPER CONDUCTOR CL. 2, ACC. TO IEC 60228, DIN VDE 0295

INSULATION

GAALTHERM® 595

CORE COLORS

PAIR: BLACK- WHITE NUMBERED:
1ST PAIR: 1-ONE, 1-ONE;
2ND PAIR: 2-TWO, 2-TWO, ETC.

TRIAD: BLACK- WHITE-RED NUMBERED:
1ST TRIAD: 1-ONE, 1-ONE, 1-ONE;
2ND TRIAD: 2-TWO, 2-TWO, 2-TWO, ETC.

STRANDING

CORE LAID-UP TOGETHER IN PAIRS/TRIADS

OVERALL SHIELD

ALUMINIUM/POLYESTER TAPE WITH TINNED ANNEALED COPPER STRANDED DRAIN WIRE

ARMOUR

TINNED ANNEALED COPPER WIRES BRAID ACC. TO IEC 60092-350

OUTER SHEATH

HALOGEN FREE THERMOPLASTIC COMPOUND SHF1 ACC. TO IEC 60092-360, THICKNESS ACC. TO IEC 60092-376

MARKING

ELETTROTEK KABEL® CABLE TYPE, CROSS NOMINAL SECTION AWG/mm2, 150/250 V, PART N°, IEC 60092-376, IEC 60332-3-22, PRODUCTION PLANT, BATCH N°, PRODUCTION DATE, CE ROHS, SEQUENTIAL METER MARKING

Features

  • SHEATHING AND INSULATING MATERIALS ACC. TO IEC 60092-360
  • DESIGN GUIDELINES ACC. TO IEC 60092-350/376
  • CHOICE AND INSTALLATION OF ELECTRIC CABLES ACC. TO IEC 60092-352
  • COLD BEND TEST AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-40°C)
  • COLD BEND IMPACT AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-35°C)
  • ON REQUEST CLASS 5 CONDUCTOR ACC. TO IEC 60228

Resistance

FLAME AND FIRE RETARDANT ACC. TO:

IEC 60332-1-2,
IEC 60332-3-22

HALOGEN FREE ACC. TO

IEC 60754-1/2

SMOKE EMISSION PROPERTIES ACC. TO

IEC 61034-1/2

Application

INSTRUMENTATION CABLES FOR FIXED ELECTRICAL INSTALLATIONS ABOARD SHIPS, SHIELDED AGAINST ELECTROMAGNETIC INTERFERENCES, COMPLYING WITH IEC 60092-352

Technical data

NOMINAL VOLTAGE :

Uo/U 150/250 V

TEMPERATURE RANGE :

INSTALLATION TEMP.

-40°C UP TO +90°C

-5°C

SHORT CIRCUIT TEMPERATURE :

+250°C

MIN. BENDING RADIUS :

4 x OUTER DIAMETER