Gaalship®

HF 1000 A FR

NXT Version, North America Color Code, armoured, fire resistant power and control cable 0,6/1 kV

Construction

CONDUCTOR

TINNED ANNEALED COPPER CONDUCTOR
CL. 2 FLEXIBLE UP TO 10 mm2
CL. 5 FROM 16 mm2, ACC. TO EN IEC 60228

INSULATION

MICA GLASS TAPE + GAALTHERM® 595

CORE COLOR

DESIGNED TO ALIGN WITH THE COLOR-CODING REQUIREMENTS AND PREFERENCES OF NORTH AMERICAN MARINE INSTALLATIONS

INNER SHEATH (IF ANY)

HALOGEN FREE COMPOUND OR SYNTHETIC TAPE

OUTER SHEATH

HALOGEN FREE THERMOPLASTIC COMPOUND TYPE SHF1, ACC. TO IEC 60092-360, THICKNESS ACC. TO IEC 60092-353

MARKING

ELETTROTEK KABEL® CABLE TYPE, CROSS NOMINAL SECTION AWG/mm2, 0,6/1 kV, PART N°, IEC 60092-353, IEC 60332-3-22, IEC 60331, PRODUCTION PLANT, BATCH N°, PRODUCTION DATE, CE ROHS, SEQUENTIAL METER MARKING.

Features

  • SHEATHING AND INSULATING MATERIALS ACC. TO: IEC 60092-360
  • DESIGN GUIDELINES ACC. TO IEC 60092-350/353
  • CHOICE AND INSTALLATION OF ELECTRIC CABLES ACC. TO IEC 60092-352
  • COLD BEND TEST AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-40°C)
  • COLD BEND IMPACT AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-35°C)
  • ON REQUEST CLASS 5 CONDUCTOR FOR SECTIONS UP TO 10 mm2

Resistance

FIRE RETARDANT ACC. TO

IEC 60331-21
IEC 60331-2 (UNDER 20 MM Ø)
IEC 60331-1 (OVER 20 MM Ø)

FLAME AND FIRE RETARDANT ACC. TO:

EN IEC 60332-1-2,
EN IEC 60332-3-22

HALOGEN FREE ACC. TO

EN IEC 60754-1/2

SMOKE EMISSION PROPERTIES ACC. TO

EN IEC 61034-1/2

Application

FIRE RESISTANT POWER AND CONTROL CABLES FOR FIXED ELECTRICAL INSTALLATIONS ABOARD SHIPS COMPLYING WITH IEC 60092-352.

Technical data

NOMINAL VOLTAGE :

Uo/U 0,6/1 kV

TEST VOLTAGE :

3,5 kV

TEMPERATURE RANGE :

INSTALLATION TEMP.

-40°C UP TO +90° C

-5°C

SHORT CIRCUIT TEMPERATURE :

+250°C

MIN. BENDING RADIUS :

4 x OUTER DIAMETER