Gaalship®

HF 1000 A EMC

NXT Version, North America Color Code, armoured, fire resistant power and control cable, EMC 0,6/1 kV

Construction

CONDUCTOR

TINNED ANNEALED COPPER CONDUCTOR
CL. 2 FLEXIBLE UP TO 10 mm2
CL. 5 FROM 16 mm2, ACC. TO EN IEC 60228

INSULATION

GAALTHERM® 595

CORE COLORS

DESIGNED TO ALIGN WITH THE COLOR-CODING REQUIREMENTS AND PREFERENCES OF NORTH AMERICAN MARINE INSTALLATIONS

INNER SHEATH (IF ANY)

HALOGEN FREE COMPOUND OR SYNTHETIC TAPE

ARMOUR

TINNED ANNEALED COPPER WIRES BRAID + 100% COVERAGE PLAIN ANNEALED COPPER/POLYESTER TAPE ACC. TO IEC 60092-350

OUTER SHEATH

HALOGEN FREE THERMOPLASTIC COMPOUND TYPE SHF1, ACC. TO IEC 60092-360, THICKNESS ACC. TO IEC 60092-353

MARKING

ELETTROTEK KABEL® CABLE TYPE, CROSS NOMINAL SECTION AWG/mm2, 0,6/1 kV, PART N°, IEC 60092-353, IEC 60332-3-22, IEC 60331, PRODUCTION PLANT, BATCH N°, PRODUCTION DATE, CE ROHS, SEQUENTIAL METER MARKING.

Features

  • SHEATHING AND INSULATING MATERIALS ACC. TO: IEC 60092-360
  • DESIGN GUIDELINES ACC. TO IEC 60092-350/353
  • CHOICE AND INSTALLATION OF ELECTRIC CABLES ACC. TO IEC 60092-352
  • COLD BEND TEST AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-40°C)
  • COLD BEND IMPACT AT LOW TEMPERATURES ACC. TO IEC 60092-350 ART. 8.9 AND ANNEX E (-35°C)
  • ON REQUEST CLASS 5 CONDUCTOR FOR SECTIONS UP TO 10 mm2

Resistance

FLAME AND FIRE RETARDANT ACC. TO:

EN IEC 60332-1-2,
EN IEC 60332-3-22

HALOGEN FREE ACC. TO

EN IEC 60754-1/2

SMOKE EMISSION PROPERTIES ACC. TO

EN IEC 61034-1/2

Application

EMC POWER AND CONTROL CABLES FOR FIXED ELECTRICAL INSTALLATIONS ABOARD SHIPS COMPLYING WITH IEC 60092-352.

Technical data

NOMINAL VOLTAGE :

Uo/U 0,6/1 kV

TEST VOLTAGE :

3,5 kV

TEMPERATURE RANGE :

INSTALLATION TEMP.

-40°C UP TO +90° C

-5°C

SHORT CIRCUIT TEMPERATURE :

+250°C

MIN. BENDING RADIUS :

4 x OUTER DIAMETER

    Request a quotation